The Mitsubishi Heavy Duty SRK18CAPDA-W is a 1.5 Ton, 2 Star split air conditioner designed to address demanding cooling requirements with high-capacity airflow and wide air distribution. With a rated cooling capacity of 5100 W, Heavy Duty Rotary Compressor, 1100 CMH airflow and Jet Airflow technology, the AC helps circulate conditioned air across the room instead of concentrating cooling only near the indoor unit.
Uneven airflow can leave parts of a room feeling warmer even while the AC is running. The SRK18CAPDA-W combines an air throw of up to 16 metres with 3D + 3D Auto Swing, helping distribute conditioned air vertically and horizontally. Its specified ambient operating capability of up to 52°C supports cooling operation during periods of intense outdoor heat.
For customers concerned about airborne particles and everyday AC maintenance, the unit includes an Anti-Viral Coated Pre Filter, PM2.5 Filter, Anti-Microbial Fan and Self-Diagnosis function. The cooling system also uses a 100% copper condenser with Blue Fin anti-corrosion coating and R32 refrigerant.
Key Features
1.5 Ton Heavy Duty Cooling
High indoor temperatures can make it difficult to bring a heated room to a comfortable temperature. The SRK18CAPDA-W provides a rated cooling capacity of 5100 W and a maximum cooling capacity of 5361 W, delivering substantial cooling output for demanding conditions.
The fixed-speed cooling system uses a Heavy Duty Rotary Compressor and is designed for customers looking for conventional non-inverter cooling operation.
Jet Airflow with Up to 16 Metre Air Throw
In deeper spaces, conditioned air may struggle to reach areas located farther from the indoor unit. Jet Airflow technology is designed to project cooled air across a greater distance, while the specified air throw of up to 16 metres helps extend airflow reach.
This helps address the problem of cooling being concentrated close to the AC while areas farther away receive less direct airflow.
1100 CMH Airflow Volume
Cooling output alone does not determine how effectively conditioned air moves through a space. The SRK18CAPDA-W delivers an airflow volume of 1100 CMH, helping circulate cooled air across the room.
The high airflow volume works together with Jet Airflow and automatic swing functions to support broader air distribution.
3D + 3D Auto Swing
Manually adjusting airflow direction can be inconvenient when cooling needs to reach different areas of a room. The 3D + 3D Auto Swing system controls horizontal and vertical airflow movement to distribute conditioned air in multiple directions.
This helps reduce concentrated airflow in one direction and supports more balanced air movement across the occupied space.
Cooling Operation Up to 52°C
Extreme outdoor temperatures place additional demand on an air conditioner. The SRK18CAPDA-W is specified for ambient operation up to 52°C, supporting cooling performance during periods of intense summer heat.
This operating range is particularly relevant during peak summer conditions when outdoor temperatures remain high for extended periods.
100% Copper Condenser
The condenser is a critical part of the air-conditioning system's heat-transfer process. The SRK18CAPDA-W uses a 100% copper condenser as part of its cooling system.
For customers comparing AC construction and heat-exchanger specifications, the copper condenser provides a clearly defined material specification for the refrigeration system.
Blue Fin Anti-Corrosion Coating
Outdoor heat exchanger components are regularly exposed to moisture and environmental conditions. The Blue Fin anti-corrosion coating provides an additional protective layer for the condenser fins.
This feature is designed to help protect the coated component against corrosive environmental exposure.
Anti-Viral Coated Pre Filter
Dust and airborne particles circulate through an air conditioner during regular operation. The Anti-Viral Coated Pre Filter provides an initial filtration stage as room air enters and passes through the indoor unit.
It forms part of the AC's multi-stage air filtration arrangement before conditioned air is circulated back into the room.
PM2.5 Filter
Fine airborne particulate matter requires a more targeted filtration stage than larger dust particles. The SRK18CAPDA-W includes a PM2.5 Filter designed to support the filtration of fine particles passing through the indoor unit.
This provides an additional filtration layer alongside the coated pre-filter.
Anti-Microbial Fan
The indoor fan continuously moves conditioned air through the AC and back into the room. The SRK18CAPDA-W uses an Anti-Microbial Fan as part of its indoor air-handling system.
This feature complements the unit's Anti-Viral Coated Pre Filter and PM2.5 filtration arrangement.
Hi Power Mode
A room that has accumulated significant heat may require stronger initial cooling operation. Hi Power Mode provides a dedicated high-performance operating setting for situations where faster temperature reduction is required.
This mode is useful when stronger cooling output is the immediate priority after starting the AC.
Sleep Mode
Maintaining the same cooling intensity throughout the night may not always match changing comfort requirements. Sleep Mode provides a dedicated operating setting intended for overnight use.
It gives users an additional operating option for extended rest periods without requiring repeated manual control changes.
Multiple Fan Speed Settings
Different cooling situations can require different airflow intensities. The SRK18CAPDA-W provides Hi Power Jet, Powerful, High, Medium and Low fan speed settings, allowing airflow to be adjusted according to current cooling and comfort requirements.
Higher settings support stronger air circulation when required, while lower settings provide more controlled airflow after the room temperature has reduced.
Multiple Indoor Sound Levels
Maximum airflow is not necessary throughout every cooling session. The indoor unit has specified sound levels of 49 dB, 44 dB, 41 dB and 39 dB across its Hi-Power, High, Medium and Low operating levels.
Users can adjust fan operation based on their immediate cooling, airflow and sound preferences.
Auto Restart Function
Power interruptions can stop AC operation and create the inconvenience of manually restarting the system. The Auto Restart function allows the air conditioner to resume operation after power is restored.
This adds convenience in locations where temporary power interruptions may occur.
Timer Function
Running an AC longer than required can be inconvenient when cooling is needed only for a defined period. The Timer function allows users to schedule AC operation according to their daily routine.
This is useful for managing cooling around sleeping, working and regular occupancy schedules.
Self-Diagnosis Function
When an operational issue occurs, identifying the cause can be difficult without technical information. The Self-Diagnosis function helps identify operating abnormalities, supporting troubleshooting and service diagnosis.
This provides useful diagnostic assistance when the air conditioner requires technical attention.
R32 Refrigerant
The SRK18CAPDA-W uses R32 refrigerant in its refrigeration circuit. The refrigerant functions as part of the AC's heat-transfer system and supports the specified cooling operation of the unit.
Technical Specifications
| Feature |
Details |
| Brand |
Mitsubishi Heavy Duty |
| Model |
SRK18CAPDA-W |
| Product Type |
Split Air Conditioner |
| AC Technology |
Hybrid Fixed Speed / Non-Inverter |
| Capacity |
1.5 Ton |
| Star Rating |
2 Star |
| ISEER |
3.9 |
| Compressor Type |
Heavy Duty Rotary Compressor |
| Rated Cooling Capacity |
5100 W |
| Maximum Cooling Capacity |
5361 W |
| Airflow Volume |
1100 CMH |
| Air Throw |
Up to 16 metres |
| Ambient Operating Temperature |
Up to 52°C |
| Condenser Type |
100% Copper |
| Fin Protection |
Blue Fin Anti-Corrosion Coating |
| Air Filters |
Anti-Viral Coated Pre Filter and PM2.5 Filter |
| Fan Type |
Anti-Microbial Fan |
| Air Swing |
3D + 3D Auto Swing |
| Cooling Modes |
Hi Power Mode, Sleep Mode |
| Fan Speed Settings |
Hi Power Jet, Powerful, High, Medium, Low |
| Indoor Sound Levels |
49 / 44 / 41 / 39 dB |
| Auto Restart |
Yes |
| Timer Function |
Yes |
| Self-Diagnosis |
Yes |
| Refrigerant |
R32 |
| Power Consumption |
1308 W at Full Load |
| Power Supply |
1 Phase, 220–230 V, 50 Hz |
| Installation Type |
Split AC |
| Manufactured By |
Mitsubishi Heavy Industries |
| Packed By |
Mitsubishi Heavy Industries |
| Country of Origin |
Thailand |
| Dimensions |
Indoor Unit: 29.5 × 100 × 23 cm; Outdoor Unit: 59.4 × 81 × 30 cm |
| Weight |
Indoor Unit: approximately 11 kg; Outdoor Unit: approximately 37.7 kg |
Warranty
• 1 Year Product Warranty
• 5 Years PCB Warranty
• 10 Years Compressor Warranty